HIGHLINE 4
Tetrapolar single lead for VDD pacing
The Highline 4 model allows to perform an effective VDD pacing with floating atrial electrodes, thanks to the 3 cm dipole which from the beginning characterizes MEDICO system: in fact it guarantees an excellent reliability of the detection of sino-atrial node, also in the long term.
It is compatible with a 7 Fr introducer and is easily handled on implant, with easy and effective positioning. The material of the electrodes is Pt-Ir with satisfactory performance both in pacing and sensing.
Physical characteristics
- electrode material: platinum-iridium
- sheath material: silicone
- distance between atrial dipole and ventricular electrode: 9, 11, 13 e 15 cm
- atrial dipole length: 30 mm
- length: 58, 62 cm
- atrial and ventricular connection: IS-1 bipolar
- suggested introducer: 7 Fr
838R PHYMOS

Single lead for VDD pacing
The 838R Phymos model allows to perform a reliable VDD pacing with floating atrial electrodes, thanks to the 3 cm dipole which from the beginning characterizes MEDICO system: in fact it guarantees an excellent reliability of the detection of sino-atrial node, also in the long term.
It is compatible with a 10 Fr introducer and is easily handled on implant, with easy and effective positioning.
The material of the ventricular electrode is Pt-Ir with satisfactory performance both in pacing and sensing.
Technical features
• ventricular electrode material: platinum-iridium
• atrial electrodes material: microporous titanium coated by platinum
• sheath material: silicone
• distance between atrial dipole and ventricular electrode: 9, 11, 13 e 15 cm
• atrial dipole length: 30 mm
• length: 68 cm (62 cm 9 and 11 cm versions)
• atrial connector: IS-1, bipolar
• ventricular connector: IS-1, unipolar
• suggested introducer: 10 Fr
838F PHYMOS

Single lead for VDD pacing
The 838F Phymos model allows to perform a reliable VDD pacing with floating atrial electrodes; in addition, thanks to a special preshape located between the atrial dipole and the ventricular tip it is possibile to stimulate the atrium by means of the same atrial electrodes.
It is compatible with a 10 Fr introducer and is easily handled on implant, with easy and effective positioning.
The material of the ventricular electrode is Pt-Ir with satisfactory performance both in pacing and sensing.
Technical features
• ventricular electrode material: platinum-iridium
• atrial electrodes material: microporous titanium coated by platinum
• sheath material: silicone
• distance between atrial dipole and ventricular electrode: 19 cm
• atrial dipole length: 15 mm
• length: 68 cm
• atrial connector: IS-1, bipolar
• ventricular connector: IS-1, unipolar
• suggested introducer: 10 Fr
Print this page